Table 1: | Heating and Air Conditioning Scan Tool Output Controls |
Table 2: | PCM Scan Tool Output Controls |
Scan Tool Output Control | Additional Menu Selection(s) | Description |
---|---|---|
Blower Motor | Miscellaneous Test | The HVAC control module commands the blower motor on to maximum speed when you select ON. The blower motor should operate at maximum speed until commanded OFF. |
Left Mix Motor | Miscellaneous Test | The HVAC control module commands the left air temperature actuator towards 255 counts when you select ON. The HVAC control module commands the left air temperature actuator towards 0 counts when commanded OFF. |
Right Mix Motor | Miscellaneous Test | The HVAC control module commands the right air temperature actuator towards 255 counts when you select ON. The HVAC control module commands the right air temperature actuator towards 0 counts when you select OFF. |
Scan Tool Output Control | Additional Menu Selection(s) | Description |
---|---|---|
A/C Relay | Engine Output Controls | The PCM energizes the A/C compressor clutch relay when you select ON. The A/C compressor clutch should remain engaged until commanded OFF. |