Removal Procedure

The instrument panel (IP) compartment is a part of the IP compartment door assembly.


    Object Number: 182592  Size: SH
  1. Open the instrument panel (IP) compartment door assembly.
  2. Loosen the screw retaining the door damper cord to the IP compartment door.
  3. Release the loop of the damper cord from the retaining screw.
  4. Rotate the IP compartment door stops ¼ turn counterclockwise to release and remove.
  5. Access the door stops from the inside of the compartment.

  6. Close the IP compartment door.
  7. Remove the screws retaining the compartment door hinge to the IP trim pad, then support the door.
  8. Carefully release the compartment door latch and remove the IP compartment door assembly.

Installation Procedure


    Object Number: 182592  Size: SH
  1. Align and insert the IP compartment door assembly into position; engage the door latch and support the door.
  2. Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.

  3. Install the IP compartment door assembly hinge to IP trim pad retaining screws.
  4. Tighten
    Tighten the IP compartment door assembly hinge to IP trim pad retaining screws to 4 N·m (35 lb in).

  5. Open the IP compartment door just enough to access the door stop retaining slots.
  6. Install the IP compartment door stops to the retaining slots, then rotate the door stops ¼ turn clockwise to secure in place.
  7. Install the loop of the door damper cord to the retaining screw on the compartment door.
  8. Tighten the door damper cord to IP compartment door retaining screw.
  9. Tighten
    Tighten the IP compartment door damper cord to IP compartment door retaining screw to 2 N·m (18 lb in).