Step | Action | Normal Results | Abnormal Results |
---|---|---|---|
1 |
|
| Refer to DTC Table . |
2 |
|
| Refer to DTC Table . |
3 | Turn the control knob to LOW SPEED |
| Refer to DTC Table . |
4 | Turn the fan control knob to HIGH SPEED |
| Refer to DTC Table . |
5 | Press thebutton |
| Refer to DTC Table . |
6 |
| The air flows from the floor outlets. The air flow becomes warm. | Refer to Air Temperature Control Inoperative . |
7 | Change the temperature control until the temperature displays 24°C (75°F). |
| Refer to Air Temperature Control Inoperative . |
8 | Place the mode selector in the DEF position | The air flows from the windshield outlets. | Refer to Defrost Air Inoperative . |
9 | Place the mode selector in the DEFOG position | The air flows from the panel, floor and windshield outlets. | Refer to Defrost Air Inoperative . |
10 | Place the mode selector in the UPPER position | The air flows from the panel outlets. | Refer to Instrument Panel Outlets Inoperative . |
11 | Place the mode selector in the LOWER position. | The air flows from the floor outlets. | Refer to Heated Air Inoperative . |
12 | Place the mode selector in the VENT position | Outside air flows from the panel outlets | Refer to Air Recirculation Always On . |
13 | Place the mode selector in the RECIRC/MAX position | Inside air is recirculated through the panel and floor outlets | Refer to Air Recirculation Inoperative . |