Removal Procedure
- Remove the air cleaner and duct assembly. Refer to
Air Cleaner Assembly Replacement
in Engine Controls.
- Disconnect the battery negative cable. Refer to
Battery Negative Cable Disconnection and Connection
in Engine
Electrical.
- Disconnect the electrical
connector from the A/C refrigerant pressure sensor.
- Remove the refrigerant
pressure sensor from the liquid line.
Installation Procedure
Important: Lubricate a new O-ring seal with mineral base 525 viscosity refrigerant
oil.
- Install the new O-ring seal.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the refrigerant
pressure sensor to the liquid line.
Tighten
Tighten the sensor to 4.7 N·m (41 lb in).
- Connect the electrical
connector to the A/C refrigerant pressure sensor.
- Connect the battery negative cable. Refer to
Battery Negative Cable Disconnection and Connection
in Engine
Electrical.
- Install the air cleaner and duct assembly. Refer to
Air Cleaner Assembly Replacement
in Engine Controls.