Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Check the HIGH BLOWER fuse in the fuse block. Is the HIGH BLOWER fuse open? | -- | Go to Step 2 | Go to Step 5 |
2 | Check for a short to ground in circuit 40 (ORN). Is there a short to ground in the circuit? | -- | Go to Step 3 | Go to Step 4 |
3 | Locate and repair the short to ground in circuit 40 (ORN). Is the repair complete? | -- | System OK | -- |
4 | Replace the blower motor resistor. Refer to Blower Motor Resistor Replacement in HVAC Systems . Is the repair complete? | -- | System OK | -- |
5 |
Does the test lamp light? | -- | Go to Step 6 | Go to Step 11 |
6 |
Does the test lamp light? | -- | Go to Step 7 | Go to Step 8 |
7 | Replace the blower motor resistor. Refer to Blower Motor Resistor Replacement in HVAC Systems . Is the repair complete? | -- | System OK | -- |
8 |
Is there a poor connection or an an open in the circuit? | -- | Go to Step 9 | Go to Step 10 |
9 | Locate and repair the fault in circuit 52 (ORN). Is the repair complete? | -- | System OK | -- |
10 | Replace the heater-A/C control. Refer to Control Assembly Replacement in HVAC Systems with A/C - Manual. Is the repair complete? | -- | System OK | -- |
11 | Locate and repair the fault in circuit 40 (ORN). Is the repair complete? | -- | System OK | -- |