Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
DEFINITION: This test checks the inflator solenoid valve and the surrounding circuits. | ||||
1 |
Is the measurement within the specified value? | 10.5--15 V | Go to Step 4 | Go to Step 2 |
2 | Check CKT 1249 (DK BLU) wiring for an open circuit condition. Is an open circuit condition present? | -- | Go to Step 3 | -- |
3 | Repair the open in CKT 1249. Is the repair complete? | -- | -- | |
4 | Measure the voltage from inflator solenoid valve connector term A to B. Is the measurement within the specified value? | 10.5--15 V | Go to Step 6 | Go to Step 5 |
5 | Repair the open circuit condition in CKT 1250 (BLK). Is the repair complete? | -- | -- | |
6 | Check air lines and fittings for binding or pinching. Are the air lines and fittings in good condition. | -- | Go to Step 8 | Go to Step 7 |
7 | Correct the air line condition. Is the condition corrected? | -- | -- | |
8 | Check the inflator solenoid valve connector for proper terminal contact. Is the connection good? | -- | Go to Step 10 | Go to Step 9 |
9 | Correct the poor connection condition. Is the connection good? | -- | -- | |
10 | Replace the inflator solenoid valve. Is the replacement complete? | -- | -- |