GM Service Manual Online
For 1990-2009 cars only

Step

Action

Value(s)

Yes

No

1

Was the instrument cluster diagnostic system check performed?

--

Go to Step 2

Go to Diagnostic System Check - Instrument Cluster

2

Verify proper operation of all of the turn lamps.

Do all of the turn lamps operate properly?

--

Go to Step 4

Go to Step 3

3

Repair any inoperative turn lamps. Refer to Turn Signal Lamps Inoperative - Hazard Lamps Operate .

Is the repair complete?

--

Go to Diagnostic System Check - Instrument Cluster

--

4

  1. Disconnect terminal A8 of the body control module (BCM) connector C2. Refer to the following procedures:
  2. •  Body Control Module Replacement in Body Control System
  3. Disconnect terminal D of turn/headlamp switch assembly connector C2.
  4. Disconnect the hazard switch.
  5. Use the J 39200 Digital Multimeter (DMM) in order to measure the resistance in CKT 16 between terminal A8 of BCM connector C2 and terminal D of turn/headlamp assembly harness connector C2.

Does the resistance measure within the specified range?

0-2 ohms

Go to Step 5

Go to Step 6

5

Replace the BCM. Refer to the following procedures:

    •  Body Control Module Replacement in Body Control System
    •  Body Control Module (BCM) Programming/RPO Configuration in Body Control System

Is the repair complete?

--

Go to Diagnostic System Check - Instrument Cluster

--

6

Repair the open in CKT 16 between terminal A8 of BCM connector C2 and terminal D of the turn/headlamp switch assembly. Refer to Wiring Repairs in Wiring Systems.

Is the repair complete?

--