• | J 39500-B R-134a
Air Conditioning Refrigerant Recovery, Recycling And Recharging System |
• | J 39893 Pressure
Testing Connector |
- With the sealing washers in place, install J 39893
on the rear head of the compressor.
- Connect the gage charging lines and J 39500-B
.
- Pressurize the suction and the high-side of the compressor using
R-134a refrigerant.
- With the compressor in a horizontal position, rotate the compressor
shaft several turns by hand in the operating direction.
- Using J 39400
,
inspect for leaks at the following locations:
5.1. | The pressure relief valve |
5.2. | The rear head switch |
5.5. | The through bolt head gaskets |
5.6. | The compressor shaft seal |
- Perform the measures necessary to correct any external leaks found.
- Inspect for leaks again following any repair.
- Recover the refrigerant.
- Disconnect the hoses from J 39893
.
- Remove J 39893
.