This DTC tests for undesired intake manifold vacuum flow to the evaporative emission (EVAP) system. The control module seals the EVAP system by commanding the EVAP canister purge solenoid valve Closed and the EVAP canister vent solenoid valve Closed. The control module monitors the fuel tank pressure (FTP) sensor to determine if a vacuum is being drawn on the EVAP system. If vacuum in the EVAP system is more than a predetermined value within a predetermined time, this DTC sets.
The following table illustrates the relationship between the ON and OFF states, and the Open or Closed states of the EVAP canister purge and vent valves.
Control Module Command | EVAP Canister Purge Solenoid Valve | EVAP Canister Vent Solenoid Valve |
---|---|---|
ON | Open | Closed |
OFF | Closed | Open |
• | DTCs P0107, P0108, P0112, P0113, P0116, P0117, P0118, P0122, P0123, P0125, P0440, P0442, P0446, P0452, P0453 are not set. |
• | The ignition voltage is between 10-18 volts. |
• | The barometric pressure (BARO) is more than 75 kPa. |
• | The fuel level is between 15-85 percent. |
• | The engine coolant temperature (ECT) is between 4-30°C (39-86°F). |
• | The intake air temperature (IAT) is between 4-30°C (39°-86°F). |
• | The start-up ECT and IAT are within 9°C (16°F) of each other. |
• | The vehicle speed sensor (VSS) is less than 121 km/h (75 mph). |
The control module detects vacuum during a non-purge condition.
• | The control module illuminates the malfunction indicator lamp (MIL) on the second consecutive ignition cycle that the diagnostic runs and fails. |
• | The control module records the operating conditions at the time the diagnostic fails. The first time the diagnostic fails, the control module stores this information in the Failure Records. If the diagnostic reports a failure on the second consecutive ignition cycle, the control module records the operating conditions at the time of the failure. The control module writes the operating conditions to the Freeze Frame and updates the Failure Records. |
• | The control module turns OFF the malfunction indicator lamp (MIL) after 3 consecutive ignition cycles that the diagnostic runs and does not fail. |
• | A current DTC, Last Test Failed, clears when the diagnostic runs and passes. |
• | A history DTC clears after 40 consecutive warm-up cycles, if no failures are reported by this or any other emission related diagnostic. |
• | Clear the MIL and the DTC with a scan tool. |
• | An intermittent condition could be caused by an improperly installed or damaged EVAP canister purge valve or a temporary blockage in the EVAP purge solenoid valve. |
• | For intermittent conditions, refer to Intermittent Conditions . |
The numbers below refer to the step numbers on the diagnostic table.
This step inspects for a leaking EVAP purge solenoid valve.
Removing the fuel fill cap will equalize the pressure inside the tank with atmospheric pressure. At 0 inches of H2O the FTP sensor should be near 1.5 volts. If the sensor is not, there is a concern with the sensor or related wiring.
Step | Action | Values | Yes | No |
---|---|---|---|---|
Schematic Reference: Evaporative Emissions Hose Routing Diagram and Engine Controls Schematics Connector End View Reference: Engine Controls Connector End Views | ||||
1 | Did you perform the Diagnostic System Check-Engine Controls? | -- | Go to Step 2 | |
Does the vacuum gage indicate an increase in vacuum? | -- | Go to Step 9 | Go to Step 3 | |
3 |
Does the vacuum gage indicate an increase in vacuum? | -- | Go to Step 5 | Go to Step 4 |
Is the Fuel Tank Pressure Sensor parameter within the specified value? | -0.5 to +0.5 in H2O | Go to Diagnostic Aids | Go to Step 8 | |
5 | Test the EVAP purge solenoid valve control circuit for a short to ground. Refer to Testing for Short to Ground and Wiring Repairs in Wiring Systems. Did you find and correct the conditions? | -- | Go to Step 11 | Go to Step 6 |
6 | Test for an intermittent and for a poor connection at the EVAP purge solenoid valve. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 11 | Go to Step 7 |
7 | Inspect for poor connections at the harness connector of the control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 11 | Go to Step 10 |
8 | Replace the FTP sensor. Refer to Fuel Tank Pressure Sensor Replacement . Did you complete the replacement? | -- | Go to Step 11 | -- |
9 | Replace the EVAP purge solenoid valve. Refer to Evaporative Emission Canister Purge Solenoid Valve Replacement . Did you complete the replacement? | -- | Go to Step 11 | -- |
10 | Replace the control module. Refer to Powertrain Control Module Replacement . Did you complete the replacement? | -- | Go to Step 11 | -- |
11 |
Did the DTC fail this ignition? | -- | Go to Step 2 | Go to Step 12 |
12 | Observe the Capture Info with a scan tool. Are there any DTCs that have not been diagnosed? | -- | System OK |