Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Power Door Systems Diagnostic System Check? | -- | Go to Step 2 | |
2 | Verify that the RH power window is inoperative from the LH door lock and side window switch. Do the power windows operate normally? | -- | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 |
Is ignition voltage present? | B+ | Go to Step 4 | Go to Step 6 |
4 | Inspect for a poor connection at the LH door lock and side window switch. Refer to Circuit Testing in wiring systems. Are the connections OK? | -- | Go to Step 6 | Go to Step 5 |
5 | Repair the connections as necessary. Refer to Wiring Repairs in wiring systems. Is the repair complete? | -- | Go to Step 7 | -- |
6 | Replace the LH door lock and side window switch. Refer to Front Side Door Window Switch Replacement Is the repair complete? | -- | Go to Step 7 | -- |
7 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 3 |