Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Power Door Systems Diagnostic System Check? | -- | Go to Step 2 | |
2 | Verify that the power mirrors are inoperative. Do the power mirrors operate normally? | -- | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 | Inspect fuse 7. Is fuse 7 open? | -- | Go to Step 4 | Go to Step 5 |
4 | Repair a short to ground in CKT 840 (ORN). Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | Go to Step 10 | -- |
5 |
Is there voltage present? | -- | Go to Step 7 | Go to Step 6 |
6 | Repair an open in CKT 840 (ORN). Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | Go to Step 10 | -- |
7 | Connect a DMM between CKT 1850 (BLK) cavity B and B+. Is there voltage present? | -- | Go to Step 8 | Go to Step 9 |
8 | Repair an open in CKT 1850 (BLK) between the rear view mirror and ground G202. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | Go to Step 10 | -- |
9 | Replace the outside rear view mirror switch. Did you complete the repair? | -- | Go to Step 10 | -- |
10 | Operate the system in order to verify the repair. Did you find and correct the condition? | -- | System OK | Go to Step 3 |