Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Power Door Systems Diagnostic System Check? | -- | Go to Step 2 | |
2 | Verify that the LF power window is inoperative. Do the power windows operate normally? | -- | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 |
Is battery voltage present? | B+ | Go to Step 7 | Go to Step 4 |
4 | Test CKT's 164 (DK BLU) and 165 (BRN) for an open. Refer to Circuit Testing in wiring systems. Was an open present? | -- | Go to Step 5 | Go to Step 6 |
5 | Repair the open in the appropriate circuit. Refer to Wiring Repairs in wiring systems. Is the repair complete? | -- | Go to Step 8 | -- |
6 | Replace the LH door lock and side window switch. Refer to Front Side Door Window Switch Replacement . Is the repair complete? | -- | Go to Step 8 | -- |
7 | Replace the LH side window regulator motor. Refer to Power Window Motor Replacement . Is the repair complete? | -- | Go to Step 8 | -- |
8 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 3 |