• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Liftgate Relay B+ | 2 | 2 | -- | -- |
Liftgate Release Switch Signal | B3265 00 | 1 | -- | -- |
Liftgate Relay High Control | B2495 02 | B2495 01 | B2495 01 | -- |
Liftgate Relay Low Control | -- | B2495 01 | B2495 01 | -- |
Liftgate Latch Control | 2 | 2 | 2 | -- |
Liftgate Release Switch Ground | -- | 1 | -- | -- |
Liftgate Latch Ground | -- | 2 | -- | -- |
1.Liftgate Release Switch Inoperative 2. Liftgate Latch Inoperative |
The liftgate switch is an input to the body control module (BCM). The BCM supplies battery voltage to the signal circuit and when the liftgate switch is activated the signal circuit voltage goes low. The BCM controls the liftgate release actuator assembly through the LIFTGATE relay. When the liftgate switch signal is activated, the BCM enables the LIFTGATE relay by applying battery voltage to the liftgate relay circuit and the relay is energized when the BCM grounds the LIFTGATE relay control circuit. When the relay is energized battery voltage is supplied to the liftgate release actuator assembly through the liftgate release actuator control circuit.
Control Module References for scan tool information
⇒ | If not the specified value, refer to Liftgate Release Switch Circuit Test. |
⇒ | If the liftgate latch does not release, refer to Liftgate Actuator Circuit Test. |
⇒ | If not the specified value, test the signal circuit terminal 2 for a short to ground. If the circuit tests normal, replace the BCM. |
⇒ | If not the specified value, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the BCM. |
⇒ | If the test lamp illuminates, test the control circuit for a short to voltage. |
⇒ | If the test lamp does not illuminate, replace the underhood fuse block. |
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. |
⇒ | If the liftgate release actuator does not activate, test the control circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the liftgate release actuator. |
⇒ | If the test lamp is always OFF, test the control circuits for a short to ground or an open/high resistance. If the circuits test normal, replace the BCM. |
⇒ | If the resistance is not within the specified range, replace the relay. |
• | 30 and 85 |
• | 30 and 86 |
• | 30 and 87 |
• | 85 and 87 |
⇒ | If not the specified value, replace the relay. |
⇒ | If greater than the specified range, replace the relay. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for BCM replacement, setup, and programming |