The air suspension inlet valve - RR is controlled by the air suspension module. The air suspension module provides a switched path to voltage whenever inlet valve activity is required. The air suspension module monitors the inlet valve circuity to determine if the voltage level agrees with the command state.
This diagnostic procedure supports the following DTC:
DTC C0717 Right Rear Solenoid 2 Circuit
The ignition is ON.
Air suspension module senses inlet valve voltage does not agree with command state.
• | Air suspension functionality is suspended. |
• | SERVICE AIR SUSPENSION message is displayed. |
The DTC will clear when the condition for setting the DTC is removed.
This DTC is set when the inlet valve circuitry is shorted to ground, voltage and open.
The numbers below refer to the step numbers on the diagnostic table.
During the right air solenoid operation, listen for an audible click. Command the ON and the OFF states. Repeat the commands as necessary.
Verifies that the air suspension module is providing voltage to the right air solenoid.
Tests for an open in the ground circuit to the right air solenoid.
Tests for constant voltage to the right air solenoid.
Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Suspension Controls Schematics | |||
1 | Did you perform the Diagnostic System Check - Vehicle? | Go to Step 2 | Go to Diagnostic System Check - Vehicle in Vehicle DTC Information |
Does the air solenoid turn ON and OFF with each command? | Go to Diagnostic Aids | Go to Step 3 | |
Probe the control circuit of the inlet valve with a test lamp that is connected to ground. Does the test lamp turn ON and OFF with each command? | Go to Step 4 | Go to Step 5 | |
Does the test lamp turn ON and OFF with each command? | Go to Step 8 | Go to Step 10 | |
Does the test lamp remain illuminated with each command? | Go to Step 7 | Go to Step 6 | |
6 | Test the control circuit of the inlet valve for a short to ground or an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 13 | Go to Step 9 |
7 | Test the control circuit of the inlet valve for a short to voltage. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 13 | Go to Step 9 |
8 | Inspect for poor connections at the inlet valve. Refer to Testing for Intermittent Conditions and Poor Connections and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 13 | Go to Step 11 |
9 | Inspect for poor connections at the harness connector of the air suspension module. Refer to Testing for Intermittent Conditions and Poor Connections and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 13 | Go to Step 12 |
10 | Repair the ground circuit of the inlet valve. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 13 | -- |
11 | Replace the air suspension inlet valve. Refer to Valve Automatic Level Control Solenoid Replacement . Did you complete the replacement? | Go to Step 13 | -- |
12 |
Did you complete the replacement? | Go to Step 13 | -- |
13 |
Does the DTC reset? | Go to Step 2 | System OK |