Step | Action | Value(s) | Yes | No | ||||||
---|---|---|---|---|---|---|---|---|---|---|
1 |
Do all of the display segments light for 2 seconds and go OFF for 2 seconds? | -- | Go to Step 2 | |||||||
2 | The self diagnostic routine is in operation. Does the display read PS for approximately 2 seconds? | -- | Go to Step 3 | Go to Step 4 | ||||||
3 | The self diagnostic routine is in operation. Does the display read N with a number within the specified range for approximately 2 seconds? | 1-14 (north-south compensation value) | Go to Step 5 | Go to Step 6 | ||||||
4 |
Is the replacement complete? | -- | -- | |||||||
5 | The self diagnostic routine is in operation. Does the display read E with a number within the specified range for approximately 2 seconds? | 1-14 (east-west compensation value) | Go to Step 7 | Go to Step 8 | ||||||
6 | Replace the compass and temperature display module. Is the replacement complete? | -- | -- | |||||||
7 | The self diagnostic routine is in operation. Does the display show a number within the specified range for approximately 2 seconds? | 1-14 | Go to Step 8 | Go to Step 6 | ||||||
8 |
Are the values between the specified values? | 6-9 |