Step | Action | Value(s) | Yes | No | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | Did the Auxiliary Power Outlets System Check bring you here? | -- | Go to Step 2 | |||||||||
2 | Inspect the auxiliary power fuse 7 at the I/P fuse block. Is the fuse functional? | -- | Go to Step 4 | Go to Step 3 | ||||||||
3 | Locate and repair the overload and replace the auxiliary power fuse. Is the repair complete? | -- | -- | |||||||||
4 | Connect a test lampJ 35616-200 from CKT 40 (ORN) cavity A to the inoperative power outlet to ground. Does the test lamp light? | -- | Go to Step 5 | Go to Step 6 | ||||||||
5 | Repair the respective opens in the following circuits:
from the power outlet to the following respective grounds:
Are the repairs complete? | -- | -- | |||||||||
6 | Repair the open in CKT 840 (ORN) between the power outlet and the instrument panel fuse block. Is the repair complete? | -- | -- |