• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Ambient Light Senor Signal | B2645 03 | B2645 07 | B2645 07 | -- |
Headlamp- Left Low Beam Control | 1 | 1 | 1 | -- |
Headlamp- Right Low Beam Control | 1 | 1 | 1 | -- |
Ambient Light Sensor Low Reference | -- | B2645 07 | B2645 07 | -- |
Headlamp- Right Low Beam Ground | -- | 1 | -- | -- |
Headlamp- Right Low Beam Ground | -- | 1 | -- | -- |
1. Headlamps Malfunction |
The ambient light/sun load sensor is used to monitor outside lighting conditions. The ambient light sensor provides a voltage signal that will vary between 0.2 and 4.9 volts depending on outside lighting conditions. The body control module (BCM) provides a 5-volt reference signal to the ambient light sensor and the HVAC control module provides a low reference ground. The BCM monitors the ambient light sensor signal circuit to determine if outside lighting conditions are correct for automatic lamp control (ALC) when the headlamp switch is in the AUTO position. In daylight conditions the BCM will command the low beam headlamps OFF. During low light conditions the BCM will command the low beam headlamps ON.
Battery voltage must be between 9-16 volts.
The BCM detects a short to ground in the ambient light sensor signal circuit.
The BCM detects a short to voltage or an open/high resistance in the ambient light sensor signal circuit.
• | Automatic lamp control (ALC) is inoperative. |
• | The BCM defaults to low light status and commands the low beam headlamps ON. |
• | The condition responsible for setting the DTC no longer exists. |
• | A history DTC will clear once 100 consecutive malfunction-free ignition cycles have occurred. |
Exterior Lighting Systems Description and Operation
Control Module References for scan tool information
⇒ | If the test lamp does not illuminate, test the low reference circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the HVAC control module. |
⇒ | If less than the specified range, test the signal circuit terminal D for a short to ground. If the circuit tests normal, replace the BCM. |
⇒ | If greater than the specified range, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the BCM. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for BCM replacement, setup, and programming |