Removal Procedure
- Remove instrument panel compartment assembly. Refer to
Instrument Panel Compartment Replacement.
- Disconnect electrical connector and remove mode control cam actuator screws (2) (Qty: 3) and remove mode control cam actuator (1).
Tip
The graphic shows Air Inlet Housing without attaching parts for better clarity.
- Remove air inlet valve and inside air valve control cam (1).
Installation Procedure
- Install air inlet valve and inside air valve control cam (1).
Tip
The air inlet valve and inside air valve control cam can only be fitted in one position.
Caution: Refer to Fastener Caution in the Preface section.
- Install mode control cam actuator (1) and Install mode control cam actuator screws (2) (Qty: 3) and connect electrical connector.
Tighten
X N·m(X lb in).
- Install instrument panel compartment assembly. Refer to
Instrument Panel Compartment Replacement.