Important: Cap or tape the open A/C lines immediately, to prevent system contamination.
Important: DO NOT install the condenser with out the rubber insulators installed on the ends of the condenser.
Important: DO NOT allow any of the mineral base 525 viscosity refrigerant oil on the new O-ring seal to enter the refrigerant system.
Allow a light coating of the refrigerant oil to remain on the compressor line in the area indicated (2) ONLY.
Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.
Tighten
Tighten the bolt to 16 N·m (11 lb ft).
Tighten
Tighten the fitting to 27 N·m (20 lb ft).