Step | Action | Value(s) | Yes | No | ||||||
---|---|---|---|---|---|---|---|---|---|---|
Tools Required
| ||||||||||
1 | Did you perform the Horns Diagnostic System Check? | -- | Go to Step 2 | |||||||
2 |
Did the test light illuminate? | -- | Go to Step 4 | Go to Step 3 | ||||||
3 | Repair the open controlled voltage CKT between the underhood fuse block connector C4 cavity A6 and the inoperative horn. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | -- | |||||||
4 | Test cavity A for continuity to ground at the inoperative horn. Refer to Testing for Continuity in Wiring Systems. Is the resistance within the specified value? | 0-5 ohms | Go to Step 5 | Go to Step 6 | ||||||
5 | Replace the inoperative horn. Refer to Horn Replacement - Left Side or Horn Replacement - Right Side . Is the repair complete? | -- | -- | |||||||
6 | Repair the open ground CKT. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- |