When the ignition switch is turned to ON, the sensing and diagnostic module (SDM) will perform a turn-on test to diagnose critical malfunctions within the SDM itself.
Upon passing this test, ignition and deployment loop voltages are measured to ensure they are within the normal voltage ranges. The SDM monitors the voltages at the driver low and the passenger low to detect shorts to ground or voltage in the deploy loops.
• | The side air bag wiring of the driver high is shorted to ground. |
• | The side air bag wiring of the driver low is shorted to ground. |
Step | Action | Values | Yes | No |
---|---|---|---|---|
Caution: Refer to Sensing and Diagnostic Module Voltage after Ignition is Turned Off Caution in the Preface section. Caution: Refer to Sensing and Diagnostic Module Handling Caution in the Preface section. | ||||
1 | Perform the Diagnostic System Check - SIR. Did you perform the Diagnostic System Check - SIR? | -- | Go to Step 2 | |
2 |
Is there any visible damage to the air bag wiring? | -- | Go to Step 4 | Go to Step 3 |
3 | Measure the resistance between the SDM and the high, low terminal of the driver side air bag module and the ground. Is the resistance equal to the specified value? | 10 K ohms | Go to Step 5 | Go to Step 4 |
4 | Replace the air bag wiring. Did you complete the replacement? | -- | -- | |
5 |
Is DTC 054 still shown as a current fault? | -- | Go to Step 6 | |
6 | Replace the driver side air bag module. Did you complete the replacement? | -- | -- |