Removal Procedure
- Remove the right instrument panel (I/P) insulator. Refer to
Instrument Panel Insulator Panel Replacement - Right Side
in Instrument
Panel, Gages, and Console.
- Remove the I/P compartment. Refer to
Instrument Panel Compartment Replacement
in Instrument Panel, Gages, and Console.
- Disconnect the electrical connector from the mode actuator.
- Remove
the screws that secure the mode actuator (1) to the HVAC module assembly.
- Remove the mode actuator from the HVAC module assembly.
Installation Procedure
- Position the mode actuator, aligning the slots in the electric actuator
drive to the flats on the shaft.
- Align the locating hole to the alignment pin on the HVAC module assembly.
- Slide the actuator drive completely onto the shaft, with the mounting
holes flush with the mounting screw holes on the HVAC module assembly.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the screws to the mode actuator (1).
Tighten
Tighten the screws to 1.5 N·m (13 lb in).
- Connect the electrical connector to the mode actuator.
- Install the I/P compartment. Refer to
Instrument Panel Compartment Replacement
in Instrument Panel, Gages, and Console.
- Install the right I/P insulator. Refer to
Instrument Panel Insulator Panel Replacement - Right Side
in Instrument Panel, Gages,
and Console.
- Calibrate the actuator. Refer to
Actuator Recalibration
in HVAC Systems - Manual.