Step | Action | Value | Yes | No | ||||||
---|---|---|---|---|---|---|---|---|---|---|
1 | Did you perform the Instrument Cluster Diagnostic System Check? | -- | Go to Step 2 | |||||||
2 |
Does the ECT gauge indicate C at 136ohms, between the C and the H at 52ohms, and H at 10ohms? | - | Go to Step 3 | Go to Step 4 | ||||||
3 | Replace the sensor. Is the repair complete? | - | - | |||||||
4 |
Is the measured resistance less than the specified values? | 5ohms | Go to Step 5 | Go to Step 7 | ||||||
5 | Inspect for high resistance in the printed circuit of the instrument panel cluster. Is the circuit OK? | - | Go to Step 6 | Go to Step 8 | ||||||
6 | Replace the ECT gauge. Is the repair complete? | - | - | |||||||
7 | Repair the YEL/WHT wire between the instrument panel cluster and the ECT sensor. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | - | - | |||||||
8 | Replace the instrument cluster printed circuit. Refer to Printed Instrument Cluster Circuit Replacement in Instrument Panel Gauges, and Console. Is the repair complete? | - | - |