Step | Action | Value | Yes | No | ||||
---|---|---|---|---|---|---|---|---|
1 | Did you perform the Instrument Cluster Diagnostic System Check? | -- | Go to Step 2 | |||||
2 |
Does the ECT gauge indicate C? | -- | Go to Step 3 | Go to Step 4 | ||||
3 | Replace the ECT sensor. Is the repair complete? | -- | -- | |||||
4 |
Is the measured resistance less than the specified range? | OL | Go to Step 5 | Go to Step 6 | ||||
5 | Repair the YEL/WHT wire between the instrument panel cluster assembly and the ECT sensor. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |||||
6 | Inspect the printed circuit of the instrument panel cluster for the following conditions:
Are the connections OK? | -- | Go to Step 7 | Go to Step 8 | ||||
7 | Replace the ECT gauge. Is the repair complete? | -- | -- | |||||
8 | Replace the instrument cluster printed circuit. Refer to Printed Instrument Cluster Circuit Replacement in Instrument Panel, Gauges and Console. Is the repair complete? | -- | -- |