Refer to
Cell 47
for schematics.
The data link connector (DLC) provides communication with the inflatable restraint sensing and diagnostic module (SDM). The DLC is under the instrument panel. The DLC supplies battery voltage and ground to the scan tool. The scan tool communicates with the SDM on the serial data line. The scan tool is connected to the DLC in order to perform the following functions:
• | Read the data list. |
• | Read the diagnostic trouble codes (DTCs). |
• | Clear the DTCs. |
When measurements are requested in this table, use J 39200 Digital Multimeter with the correct terminal adapter from J 35616 Connector Test Adapter Kit. When a check for proper connection is requested, refer to General Electrical Diagnosis Procedures in Wiring Systems. When a wire, connector or terminal repair is requested, use J-38125 Terminal Repair Kit and refer to Wiring Repair .
This test checks for an open or for a high resistance condition in the SDM ground circuit.
This test checks for an open or for a high resistance condition in the SDM voltage feed circuit.
This test checks for an open or for a high resistance condition in the serial data circuit.
This test checks for a short to ground condition in the serial data circuit.
This test checks for a short to voltage condition in the serial data circuit.
This test checks for a short to ground condition in the SDM voltage feed circuit.
Step | Action | Values | Yes | No |
---|---|---|---|---|
1 | Did you perform the SIR Diagnostic System Check? | -- | Go to Step 2 | |
2 |
Is the fuse open? | -- | Go to Step 8 | Go to Step 3 |
Is the resistance within the specified range? | 0-2 ohms | Go to Step 4 | Go to Step 11 | |
Is the voltage within the specified range? | Battery Voltage | Go to Step 5 | Go to Step 12 | |
Connect a J 39200 DMM between terminal 9 of the Data Link Connector (DLC) and terminal 1 of the SDM connector in order to measure the resistance. Is the resistance within the specified range? | 0-2 ohms | Go to Step 6 | Go to Step 13 | |
Connect a J 39200 DMM between terminal 9 of the DLC and ground in order to measure the resistance. Is the resistance within the specified range? | OL (Infinite) | Go to Step 7 | Go to Step 14 | |
Is the voltage within the specified range? | 0-1 V | Go to Step 16 | Go to Step 15 | |
Is the resistance within the specified range? | OL (Infinite) | Go to Step 9 | Go to Step 10 | |
9 |
Are the repairs complete? | -- | -- | |
10 |
Is the repair complete? | -- | -- | |
11 | Repair the open or the high resistance condition in the BLK/WHT wire between the SDM and G204. Refer to Wiring Repair . Is the repair complete? | -- | -- | |
12 | Repair the open or the high resistance condition in the YEL/BLK wire between the SDM and the junction block. Refer to Wiring Repair . Is the repair complete? | -- | -- | |
13 | Repair the open or the high resistance condition in the PPL wire or in the PPL/RED wire between the SDM and the DLC. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
14 | Repair the short to ground in the PPL wire or in the PPL/RED wire between the SDM and the DLC. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
15 | Repair the short to voltage in the PPL wire or in the PPL/RED wire between the SDM and the DLC. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
16 | Replace the SDM. Refer to Inflatable Restraint Sensing and Diagnostic Module Replacement . Is the repair complete? | -- | -- |