Step | Action | Yes | No | ||||||
---|---|---|---|---|---|---|---|---|---|
1 | Was the HVAC System Check performed? | Go to Step 2 | Go to HVAC System Check | ||||||
2 |
Does the blower motor stop? | Go to Step 3 | Go to Step 4 | ||||||
3 | Replace the blower speed selector switch. Refer to Control Assembly Replacement . Is the repair complete? | Go to HVAC System Check | -- | ||||||
4 | Backprobe the connector of the blower motor with a test lamp from terminal 2 to ground. Does the test lamp light? | Go to Step 5 | Go to Step 6 | ||||||
5 | Repair the short to voltage in the PNK wire between the following components:
Is the repair complete? | Go to HVAC System Check | -- | ||||||
6 | Backprobe the connector of the blower motor resistor with a test lamp from terminal 1 to ground. Does the test lamp light? | Go to Step 7 | Go to Step 8 | ||||||
7 | Repair the short to voltage in the PNK/BLU wire between the blower motor resistor and the blower speed selector switch. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | Go to HVAC System Check | -- | ||||||
8 | Backprobe the connector of the blower motor resistor with a test lamp from terminal 3 to ground. Does the test lamp light? | Go to Step 9 | Go to Step 10 | ||||||
9 | Repair the short to voltage in the PNK/GRN wire between the blower speed selector switch and the blower motor resistor. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | Go to HVAC System Check | -- | ||||||
10 | Repair the short to voltage in the PNK/BLK wire between the blower speed selector switch and the blower motor resistor. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | Go to HVAC System Check | -- |