GM Service Manual Online
For 1990-2009 cars only

Removal Procedure


    Object Number: 622098  Size: SH
  1. Remove the instrument panel cluster. Refer to Instrument Cluster Replacement .
  2. Important: Remember the location of the bulb sockets (3,4) for proper installation.

  3. Remove all of the bulb sockets (3,4) from the back of the cluster (6).

  4. Object Number: 351466  Size: SH
  5. Remove the screws (1,2,3,4) from the back of the instrument cluster assembly.

  6. Object Number: 622098  Size: SH
  7. Remove the printed circuit (1) from the back of the instrument cluster (6).

Installation Procedure


    Object Number: 622098  Size: SH
  1. Install the printed circuit (1) to the back of the instrument cluster (6).

  2. Object Number: 351466  Size: SH
  3. Secure the printed circuit with all of the gauge screws (1,2,3,4).

  4. Object Number: 622098  Size: SH
  5. Install all of the bulb sockets (3,4) to the back of the instrument cluster (6).
  6. Install the instrument panel cluster. Refer to Instrument Cluster Replacement .