The numbers below refer to the step numbers in the diagnostic table.
There are 2 blower motor supply voltage circuits at the blower motor relay. Probe the circuit that is connected to the blower motor resistor assembly.
There are 2 ignition 3 voltage circuits at the HVAC control assembly. Probe the circuit that is the supply voltage to the blower motor switch.
Step | Action | Yes | No | ||||||
---|---|---|---|---|---|---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: The blower motor is inoperative in all speed positions. | |||||||||
1 | Did you perform the Diagnostic System Check - Vehicle? | Go to Step 2 | |||||||
2 |
Does the blower motor operate in any speed position? | Go to Blower Motor Malfunction | Go to Step 3 | ||||||
3 |
Does the test lamp illuminate? | Go to Step 4 | Go to Step 5 | ||||||
4 | Test the ground circuit of the blower motor for an open or high resistance. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 15 | Go to Step 9 | ||||||
5 | Test the blower motor supply voltage circuit between the blower motor and the blower motor relay for the following:
Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 15 | Go to Step 6 | ||||||
Does the test lamp illuminate? | Go to Step 8 | Go to Step 7 | |||||||
Does the test lamp illuminate? | Go to Step 10 | Go to Step 11 | |||||||
8 | Inspect for poor connections at the harness connector of the blower motor relay. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 15 | Go to Step 12 | ||||||
9 | Inspect for poor connections at the harness connector of the blower motor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 15 | Go to Step 13 | ||||||
10 | Inspect for poor connections at the harness connector of the HVAC control assembly. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 15 | Go to Step 14 | ||||||
11 | Repair the ignition 3 voltage circuit of the HVAC control assembly. Refer to Wiring Repairs . Did you complete the repair? | Go to Step 15 | -- | ||||||
12 | Replace the blower motor relay. Did you complete the replacement? | Go to Step 15 | -- | ||||||
13 | Replace the blower motor. Refer to Blower Motor Replacement . Did you complete the replacement? | Go to Step 15 | -- | ||||||
14 | Replace the HVAC control assembly. Refer to HVAC Control Module Replacement . Did you complete the replacement? | Go to Step 15 | -- | ||||||
15 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 3 |