J 39194-B Heated Oxygen Sensor Wrench
Important: The rear exhaust pipe and catalytic converter are only serviced as an assembly; components are not serviced separately.
Important: The heated oxygen sensor (HO2S) 2 uses a permanently attached pigtail and connector. This pigtail should not be removed from the sensor. Damage or removal of the pigtail or connector will affect proper operation of the sensor.
Exhaust Pipe to Manifold Flange Warpage:
• | Service Limit: 0.7 mm (0.028 in) max. |
• | Standard: 0.7 mm (0.028 in) max. |
Notice: Refer to Fastener Notice in the Preface section.
Tighten
Tighten the exhaust pipe-to-manifold nut and bolts to 31 N·m (23 lb ft).
Tighten
Tighten the catalytic convertor to crossover pipe nuts to 31 N·m (23 lb ft).
Tighten
Tighten the oxygen-sensor-to-exhaust manifold to 45 N·m (33 lb ft).
J 39194-B Heated Oxygen Sensor Wrench
Important: The front exhaust pipe and catalytic converter are only serviced as an assembly; components are not serviced separately.
Important: The heated oxygen sensor (HO2S) 2 uses a permanently attached pigtail and connector. This pigtail should not be removed from the sensor. Damage or removal of the pigtail or connector will affect proper operation of the sensor.
Exhaust Pipe to Manifold Flange Warpage:
• | Service Limit: 0.7 mm (0.028 in) max. |
• | Standard: 0.7 mm (0.028 in) max. |
Notice: Refer to Fastener Notice in the Preface section.
Tighten
Tighten the exhaust pipe-to-manifold nut and bolts to 31 N·m (23 lb ft).
Tighten
Tighten the catalytic convertor to crossover pipe nuts to 31 N·m (23 lb ft).
Tighten
Tighten the oxygen-sensor-to-exhaust manifold to 45 N·m (33 lb ft).