Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Was the Cigar Lighter/Auxiliary Outlets System Description reviewed? | -- | ||
2 | Check the Fuse 1. Is the Fuse 1 open? | -- | ||
3 | Using a test light, probe between the cigar lighter terminal A and ground. Is the test light on? | -- | ||
4 | Use a test light, probe between the cigar lighter terminals A and B. | -- | ||
5 | Repair short to ground in the Fuse Output-Battery Circuit. Refer to Testing for Short to Ground and Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
6 | Repair poor connection or open in Fuse Output-Battery circuit. Refer to Testing for Intermittent Conditions and Poor Connections and Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
7 | Repair poor connection or open in ground circuit. Refer to Testing for Intermittent Conditions and Poor Connections and Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
8 | Replace the cigar lighter. Refer to Cigar Lighter Housing Replacement - Instrument Panel in Instrument Panel, Console and Gauges Systems Is the repair complete? | -- | -- | |
9 | Push in cigar lighter into cigar lighter housing, all the way until it locks in place. Does the cigar lighter pop out of the cigar lighter housing with its filament hot? | -- | System OK |