Step
| Action
| Value(s)
| Yes
| No
|
1
| Did you perform the
Remote Keyless Entry System Check?
| --
| Go
to
Step 2
| Go to
Remote Keyless Entry System Check
|
2
|
- Reprogram all transmitters. Refer to
Transmitter Programming
.
- Perform the LOCK feature again.
Does the LOCK function work on all of the doors after performing the
transmitter programming procedure?
| --
| Go to
Remote Keyless Entry System Check
| Go to
Step 3
|
3
|
- Turn the ignition switch to the LOCK position.
- Disconnect the Remote Control Door Lock Receiver (RCDLR) connector.
- Disconnect the door lock relay connector.
- Measure the resistance between the RCDLR harness connector terminal R
and door lock relay harness connector terminal A using a J 39200
digital multimeter (DMM).
Is the resistance less than the specified value?
| 2ohms
| Go to
Step 4
| Go to
Step 5
|
4
|
- Reconnect the door lock relay.
- Momentarily connect between B+ and the RCDLR harness connector
terminal R using a 10A fused jumper.
Do all of the doors lock?
| --
| Go to
Step 6
| Go to
Step 7
|
5
| Repair the following conditions in CKT 195:
Has the repair been made?
| --
| Go to
Step 8
| --
|
6
|
- Inspect the RCDLR connector for poor terminal contact.
- Replace the RCDLR if the connector is OK. Refer to
Receiver Replacement
.
Has the repair been made?
| --
| Go to
Step 8
| --
|
7
|
- Use a test light to probe between the door lock relay terminal B
and the ground.
- Press either door lock switch to the lock position.
Does the test light illuminate?
| --
| Go to
Step 9
| Go to
Step 10
|
8
|
- Ensure that the ignition switch is in the LOCK position.
- Reconnect any connectors that have been previously disconnected.
- Install any components that have been previously removed.
Have all the repairs been made?
| --
| Go to
Remote Keyless Entry System Check
| --
|
9
| Repair the poor connection or an open in circuit 295
between the door lock relay terminal B and S315.
Has the repair been made?
| --
| Go to
Step 8
| --
|
10
|
- Inspect the door lock relay connector for poor terminal contact.
- Replace the door lock relay if the connector is OK.
Has the repair been made?
| --
| Go to
Step 8
| --
|