Step | Action | Value(s) | Yes | No | ||||
---|---|---|---|---|---|---|---|---|
Important: Complete the following steps before you measure the resistance of the
antenna:
| ||||||||
1 |
Caution: Unless directed otherwise, the ignition and start switch must be in the OFF or LOCK position, and all electrical loads must be OFF before servicing any electrical component. Disconnect the negative battery cable to prevent an electrical spark should a tool or equipment come in contact with an exposed electrical terminal. Failure to follow these precautions may result in personal injury and/or damage to the vehicle or its components. Is the reading greater than the specified value? | 0.15 ohms | Go to Step 8 | Go to Step 2 | ||||
2 |
Does the meter indicate continuity intermittently? | -- | Go to Step 8 | Go to Step 3 | ||||
3 | Is the coax cable type RG-58 or RG-59? | -- | Go to Step 4 | Go to Step 5 | ||||
4 | Is the measured resistance less than the specified value? | 0.2 ohms | Go to Step 6 | Go to Step 7 | ||||
5 | For RG-62 or RG-62M, is the measured resistance less than the specified value? | 3.5 ohms | Go to Step 6 | Go to Step 7 | ||||
6 | While observing the J 39200 DMM, wiggle the antenna coax. Does the meter indicate continuity intermittently? | -- | Go to Step 7 | Go to Step 8 | ||||
7 | Replace coaxial cable. Refer to Radio Antenna Cable Extension Cable Replacement for service procedure. Is the repair complete? | -- | Go to Radio/Audio System Check | -- | ||||
8 | Replace the antenna. Refer to Fixed Antenna Mast Replacement or Radio Antenna Replacement for service procedure. Is the repair complete? | -- | Go to Radio/Audio System Check | -- |