When you first turn the ignition switch to the RUN position, the inflatable restraint Sensing and Diagnostic Module (SDM) performs tests in order to diagnose critical malfunctions within the module. Upon passing the tests, IGNITION 1, 23VLR and the deployment loop voltages are measured in order to ensure that the voltages are within the respective normal voltage ranges. The SDM monitors the voltages at DRIVER SIDE LOW terminal 3 and PASSENGER SIDE LOW terminal 4 in order to detect shorts-to-B+ in the inflator module circuits.
• | The voltage at PASSENGER SIDE LOW terminal 4 is less than 4.8 volts. |
• | The voltage at DRIVER SIDE LOW terminal 3 is more than 4.8 volts for 500 milliseconds. |
The CONTINUOUS MONITORING test checks for this DTC. This test occurs when IGNITION 1 is within the normal operating voltage range.
• | The SDM sets a Diagnostic Trouble Code. |
• | The SDM turns ON the AIR BAG warning lamp. |
• | Current DTC |
The voltage at DRIVER SIDE LOW terminal 3 is less than 4.8 volts for 500 milliseconds. |
• | History DTC |
- | You issue a scan tool CLEAR CODES command. |
- | Once 250 malfunction free ignition cycles have occurred. |
A short-to-B+ in the inflatable restraint steering wheel module circuit may cause an intermittent condition. Carefully inspect CKT 347 and CKT 348 for cutting or chafing. The diagnostic table directs the technician to note the entry value of DRIVER SENSELO. Comparing the value of DRIVER SENSELO may be helpful in determining if an intermittent condition exists.
When measurements are requested in this table, use the J 39200 DMM with the correct terminal adapter from the J 35616 Connector Test Adapter Kit. When an inspection for proper connection is requested, refer to Testing for Electrical Intermittents in Wiring Systems. When a wire, connector or terminal repair is requested, use the J-38125 Terminal Repair Kit and refer to Wiring Repairs in Wiring Systems.
The numbers below refer to the step numbers on the diagnostic table:
This test determines the driver side low voltage measured by the inflatable restraint Sensing and Diagnostic Module (SDM).
This test isolates the malfunction to one side of the inflatable restraint steering wheel module coil yellow 2-way connector.
This test determines whether the malfunction is due to the inflatable restraint steering wheel module or the module coil.
This test determines whether the malfunction is in CKT 347.
This test determines whether the malfunction is in CKT 348.
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Was the SIR Diagnostic System Check performed? | -- | ||
Has the DRIVER SENSELO been read and recorded on the repair order? | -- | -- | ||
Is DRIVER SENSELO more than the specified value? | 4.8 V | |||
Is DRIVER SENSELO more than the specified value? | 4.8 V | |||
5 |
Are the repairs complete? | -- | -- | |
6 |
Are the repairs complete? | -- | -- | |
Is the measured voltage less than the specified value? | 1.0 V | |||
8 |
Are the repairs complete? | -- | -- | |
Measure the voltage on the SDM harness connector from terminal 3 to terminal 6 (ground). Is the measured voltage less than the specified value? | 1.0 V | Go to Integrity Check | ||
10 |
Are the repairs complete? | -- | -- | |
11 | Reconnect all the SIR components, make sure all the components are properly mounted. Have all the SIR components been reconnected and properly mounted? | -- | -- | |
12 | Clear all the SIR DTCs. Have all the SIR DTCs been cleared? | -- | -- |