• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open | Short to Voltage |
---|---|---|---|
Catalytic Converter 1 Sensor Signal | P0545 | P0546 | P0546 |
Circuit | Short to Ground | Open | Short to Voltage |
---|---|---|---|
Operating Conditions: Ignition ON Parameter Normal Range: 0-1000°C (32-1832°F) | |||
Catalytic Converter 1 Sensor Signal | 1000°C (1832°F) | 0°C (32°F) | 0°C (32°F) |
The engine control module (ECM) supplies 5 volts to the exhaust gas temperature 1 sensor on the 5-volt reference circuit. The ECM also provides a ground on the low reference circuit. The exhaust gas temperature 1 sensor provides a signal to the ECM on the exhaust gas temperature 1 signal circuit which is relative to the pressure changes in the manifold. The ECM should detect a low signal voltage at a exhaust gas temperature 1, such as low engine load. The ECM should detect high signal voltage at a high exhaust gas temperature 1, such as high engine load. The ECM monitors the exhaust gas temperature 1 sensor signal for voltage outside the normal range of the exhaust gas temperature 1 sensor.
• | The battery voltage is between 10-16 volts. |
• | The ignition switch is ON for longer than 2 seconds. |
• | The DPF status is normal. The DPF differential pressure status is one, and the DPF warning counter status is 2. |
The ECM detects that the catalyst temperature is continuously low.
DTC P244C is a Type A DTC.
DTC P244C is a Type A DTC.
An incorrectly installed DOC exhaust gas temperature sensor will cause this DTC to set.
• | Circuit Testing |
• | Wiring Repairs |
Powertrain Diagnostic Trouble Code (DTC) Type Definitions
Verify the integrity of the engine exhaust system and fuel system by inspecting for the following conditions:
• | Damaged components |
• | Loose or improper installation |
Important: You must perform Circuit/System Verification before proceeding with Circuit/System Testing.
⇒ | If less than 4.8 volts, test the low reference circuit for an open/high resistance. |
⇒ | If greater than the specified range, test the signal circuit for a short to ground. If the circuit tests normal, replace the control module. |
⇒ | If less than the specified range, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the control module. |
⇒ | If all circuits test normal, test or replace the exhaust gas temperature 1 sensor. |
⇒ | If detect the DTC, replace the control module. |
⇒ | If a broken, clogged, or melted DPF filter is found, replace the DPF filter. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | DOC Exhaust Gas Temperature Sensor Replacement |
• | DPF Filter Replacement setup, and programming |
• | Control Module References for ECM replacement, setup, and programming |