Removal Procedure


    Object Number: 1556020  Size: SH
  1. Disconnect the positive crankcase ventilation (PCV) tube from the air inlet duct. Refer to Plastic Collar Quick Connect Fitting Service .
  2. Loosen the air cleaner outlet duct clamp at the throttle body.
  3. Remove the air cleaner outlet duct from the throttle body.
  4. Loosen the air cleaner outlet duct clamp at the mass air flow (MAF)/intake air temperature (IAT) sensor.
  5. Remove the air cleaner outlet duct from the MAF/IAT sensor.

Installation Procedure


    Object Number: 1556020  Size: SH
  1. Install the air cleaner outlet duct from the MAF/IAT sensor.
  2. Notice: Refer to Fastener Notice in the Preface section.

  3. Tighten the air cleaner outlet duct clamp at the MAF/IAT sensor.
  4. Tighten
    Tighten the clamp to 3 N·m (27 lb in).

  5. Install the air cleaner outlet duct to the throttle body.
  6. Tighten the air cleaner outlet duct clamp at the throttle body.
  7. Tighten
    Tighten the clamp to 3 N·m (27 lb in).

  8. Connect the PCV tube to the air inlet duct. Refer to Plastic Collar Quick Connect Fitting Service .