Heater Pipes Replacement RPO LS4
Tools Required
J 38185
Hose Clamp Pliers
Removal Procedure
- Remove the air cleaner assembly. Refer to
Air Cleaner Assembly Replacement
.
- Drain the cooling system. Refer to
Cooling System Draining and Filling
.
- Release and reposition the heater inlet and outlet hose clamps using the
J 38185
.
Important: Cap or plug the cooling components to prevent system contamination.
- Remove the heater hoses from heater pipes.
Notice: Do not apply excessive force on the heater core pipes during hose removal.
Applying excessive force on the heater core pipes may damage the heater core
pipes.
- Remove the heater pipe assembly retaining bolts from the rear the of engine.
- Remove the heater pipe assembly retaining bolt from the front of the engine.
- Release and reposition the heater pipe hose clamps at the engine using the
J 38185
.
- Remove the heater pipe hoses from the engine.
- Remove the heater pipe assembly from the vehicle.
Installation Procedure
- Using a lint-free clean, dry cloth, carefully clean the sealing surfaces of the heater pipe assembly at the
engine and heater hoses.
- Install the heater pipe assembly into position in the vehicle.
- Install the heater pipe hoses to the engine.
- Reposition and release the heater pipe hose clamps at the engine using the
J 38185
.
- Loosely install the heater pipe assembly retaining bolt to the front of the engine.
Notice: Refer to Fastener Notice in the Preface section.
- Install the heater pipe assembly retaining bolts to the rear of the engine.
Tighten
Tighten all the heater pipe assembly bolts to 16 N·m (12 lb ft).
- Connect heater hoses to the heater pipe assembly.
- Install the heater hose clamps into position using the
J 38185
.
- Install the air cleaner assembly. Refer to
Air Cleaner Assembly Replacement
.
- Fill the cooling system. Refer to
Cooling System Draining and Filling
.
Heater Pipes Replacement RPOs LZE, LZ4, LZ9
Callout
| Component Name
|
Notice: Refer to Fastener Notice in the Preface section. Fastener Tightening Specifications:
Refer to
Fastener Tightening Specifications
.
Preliminary Procedure
- Drain the cooling system. Refer to
Cooling System Draining and Filling
.
- Remove heater inlet hose from the heater pipe assembly. Refer to
Heater Inlet Hose Replacement
.
- Remove heater outlet hose from the heater pipe assembly. Refer to
Heater Outlet Hose Replacement
.
- Remove the air cleaner duct. Refer to
Air Cleaner Resonator Outlet Duct Replacement
.
|
1
| Nut, Pipe Assembly - Heater Inlet and Outlet Pipe - Left
Tighten 10 N·m (89 lb in) |
2
| Pipe Assembly, Heater Inlet and Outlet Pipe - Left
Tip Using the
J 38185
disconnect the left heater pipe assembly from the front heater pipe assembly. |
3
| Bolt, Pipe Assembly - Heater Inlet and Outlet Pipe - Front
Tighten 25 N·m (18 lb in) |
4
| Stud, Pipe Assembly - Heater Inlet and Outlet Pipe - Front
Tighten 10 N·m (89 lb in) |
5
| Pipe Assembly, Heater Inlet and Outlet Pipe - Front
|