HVAC Control Module Replacement C60
Removal Procedure
- Remove the instrument panel trim plate bezel. Refer to
Instrument Panel Cluster Trim Plate Bezel Replacement
in Instrument
Panel, Gauges and Console.
- Remove the front floor console, if equipped. Refer to
Front Floor Console Replacement
in Instrument
Panel, Gauges and Console.
- Remove the retaining screws
from the HVAC control module.
- Pull the HVAC control module out from the instrument panel.
- Disconnect the electrical
connectors (1) from the HVAC control module.
- Disconnect the vacuum connectors (2) from the HVAC control
module.
- Remove the HVAC control module from the instrument panel.
Installation Procedure
- Connect the electrical
connectors (1) the HVAC control module.
- Connect the vacuum connectors (2) to the HVAC control module.
- Install the HVAC control
module into the instrument panel.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the retaining
screws to secure the HVAC control module.
Tighten
Tighten the HVAC control module retaining screw to 1.8 N·m
(16 lb in).
- Install the instrument panel trim plate bezel. Refer to
Instrument Panel Cluster Trim Plate Bezel Replacement
in Instrument
Panel, Gauges and Console.
- Install the front floor console, if equipped. Refer to
Front Floor Console Replacement
in Instrument
Panel, Gauges and Console.
HVAC Control Module Replacement CJ3
Removal Procedure
- Remove the instrument panel trim plate bezel. Refer to
Instrument Panel Cluster Trim Plate Bezel Replacement
in Instrument
Panel, Gauges and Console.
- Remove the front floor console, if equipped. Refer to
Front Floor Console Replacement
in Instrument
Panel, Gauges and Console.
- Remove the retaining screws
from the HVAC control module.
- Pull the HVAC control module out from the instrument panel.
- Disconnect the electrical
connectors (1) from the HVAC control module.
- Disconnect the vacuum connectors (2) from the HVAC control
module.
- Remove the HVAC control module from the instrument panel.
Installation Procedure
- Connect the electrical
connectors (1) to the HVAC control module.
- Connect the vacuum connectors (2) to the HVAC control module.
- Install the HVAC control
module into the instrument panel.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the retaining
screws to secure the HVAC control module.
Tighten
Tighten the control module retaining screw to 1.8 N·m (16 lb
in).
- Install the instrument panel trim plate bezel. Refer to
Instrument Panel Cluster Trim Plate Bezel Replacement
in Instrument
Panel, Gauges and Console.
- Install the front floor console, if equipped. Refer to
Front Floor Console Replacement
in Instrument
Panel, Gauges and Console.