The powertrain control module (PCM) continuously monitors the heated oxygen sensor (HO2S) activity for 100 seconds. During the monitoring period, the PCM counts the number of times that a rich-to-lean and lean-to-rich response is indicated and adds the amount of time necessary to complete all transitions. With this information, an average time for each transition can be determined. If the average response time is too slow, a DTC P0133 will be set.
A lean-to-rich transition is indicated when the HO2S voltage changes from less than 300 mV to more than 600 mV. A rich-to-lean transition is indicated when the HO2S voltage changes from more than 600 mV to less than 300 mV. An HO2S that responds too slowly is likely to be inoperative and should be replaced.
• | DTCs P0101, P0102, P0103, P0106, P0107, P0108, P0112, P0113, P0117, P0118, P0121, P0122, P0123, P0125, P0128, P0201-P0206, DTC P0410, P0440, P0442, P0443, P0446, P0449, or P1441 are not set. |
• | The transmission is not in Park or Neutral. |
• | The engine has been running for at least 4 minutes. |
• | The mass air flow (MAF) is between 8 and 35 g/s. |
• | The engine speed is between 550-3000 RPM. |
• | The throttle angle is between 3-35 percent. |
• | The system voltage is between 9-18 volts. |
• | The engine coolant temperature (ECT) is more than 70°C (158°F). |
• | The HO2S 1 lean-to-rich average transition response time was more than 95 milliseconds. |
• | The HO2S 1 rich-to-lean average transition response time was more than 105 milliseconds. |
• | The control module illuminates the malfunction indicator lamp (MIL) on the second consecutive ignition cycle that the diagnostic runs and fails. |
• | The control module records the operating conditions at the time the diagnostic fails. The first time the diagnostic fails, the control module stores this information in the Failure Records. If the diagnostic reports a failure on the second consecutive ignition cycle, the control module records the operating conditions at the time of the failure. The control module writes the operating conditions to the Freeze Frame and updates the Failure Records. |
• | The control module turns OFF the malfunction indicator lamp (MIL) after 3 consecutive ignition cycles that the diagnostic runs and does not fail. |
• | A current DTC, Last Test Failed, clears when the diagnostic runs and passes. |
• | A history DTC clears after 40 consecutive warm-up cycles, if no failures are reported by this or any other emission related diagnostic. |
• | Clear the MIL and the DTC with a scan tool. |
The numbers below refer to the step numbers on the diagnostic table.
This step verifies that the malfunction is currently present during the average rich-to-lean and lean-to-rich transition times. With the ignition turned ON, the scan tool indicates the results of the last test for this diagnostic. The test conditions must be met in order for the scan tool to update the results of the test for this ignition cycle.
HO2S transition time, ratio, and switching DTCs set for multiple sensors indicate probable contamination. Before replacing the sensors, isolate and correct the source of the contamination to avoid damaging the replacement sensors.
Step | Action | Yes | No | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: Engine Controls Schematics | |||||||||||
1 | Did you perform the Diagnostic System Check-Engine Controls? | Go to Step 2 | |||||||||
Important: If any DTCs are set, except P1134, refer to those DTCs before proceeding with this diagnostic table. Refer to Diagnostic Trouble Code (DTC) List to diagnose the applicable DTC.
Does the scan tool indicate DTC P0133 failed last test? | Go to Step 3 | Go to Intermittent Conditions | |||||||||
Does the scan tool also indicate DTC P1134 failed last test? | Go to Step 6 | Go to Step 4 | |||||||||
4 |
Did you find and correct a condition? | Go to Step 7 | Go to Step 5 | ||||||||
5 |
Did you find and correct the condition? | Go to Step 7 | Go to Step 6 | ||||||||
6 |
Notice: Correct the source of the oxygen sensor contamination before replacing
the sensor in order to prevent future contamination. Typical contamination
sources include the following:
Replace the bank 1 heated oxygen sensor. Refer to Heated Oxygen Sensor 1 Replacement . Did you complete the replacement? | Go to Step 7 | -- | ||||||||
7 |
Does the DTC run and pass? | Go to Step 8 | Go to Step 2 | ||||||||
8 | With a scan tool, observe the stored information, Capture Info. Does the scan tool display any DTCs that you have not diagnosed? | System OK |