Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure.
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Relay Switch B+ Circuit | 2 | 2 | -- | -- |
Rear Defogger Relay Control | B0283 02 | B0283 05 | B0283 05 | -- |
Relay Controlled Output Circuit | 2 | 2 | 3 | -- |
Rear Defogger Switch Signal | 2 | 2 | 2 | -- |
Defog Switch Ground | -- | 1,2 | 1,2 | -- |
Rear Window Defogger Grid Ground | -- | 2 | 2 | -- |
Relay Coil Ground Circuit | -- | 2 | 2 | -- |
1. HVAC Defogger Indicator Inoperative 2. Rear Defogger Inoperative 3. Rear Defogger Always ON |
The body control module (BCM) monitors the voltage level on the supply voltage circuit of the RDFG relay. The voltage level should be low while the REAR DEFOG relay is de-energized. The voltage will be near system voltage when the BCM energizes the REAR DEFOG relay.
Battery voltage must be between 9-16 volts.
This DTC will set when the BCM detects a short to ground in the rear defog relay control circuit or defogger indicator voltage supply circuit for 1 second or greater.
This DTC will set when the BCM detects a short to voltage or an open/high resistance in the rear defog relay control circuit or rear defog indicator voltage supply circuit for 1 second or greater.
• | The BCM stores the DTC to memory. |
• | The rear window defogger will not operate. |
• | This DTC will change from current to history when the fault is no longer present. |
• | A history DTC will clear after 100 consecutive ignition cycles if the condition for the malfunction is no longer present. |
• | The technician issues a scan tool CLEAR DTCs command. |
Stationary Windows Connector End Views
Rear Window Defogger Description and Operation
⇒ | If the rear window defogger does not turn ON and OFF when changing between the commanded states, refer to Rear Defogger Malfunction. |
⇒ | If the Defogger Indicator does not illuminate or continuously illuminates, refer to Rear Defogger Indicator Malfunction. |
⇒ | If greater than the specified range, test the relay coil ground circuit for an open/high resistance. |
⇒ | If the test lamp is always ON, test the rear defogger relay control circuit for a short to voltage. If the circuit tests normal, replace the BCM. |
⇒ | If the test lamp is always OFF, test the rear defogger relay control circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the BCM |
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. |
⇒ | If the test lamp is always ON, test the control circuit for a short to voltage. If the circuit tests normal, replace the BCM. |
⇒ | If the test lamp is always OFF, test the control circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the BCM. |
⇒ | If the resistance is not withnin the specified range, replace the relay. |
• | 30 and 86 |
• | 30 and 87 |
• | 30 and 85 |
• | 85 and 87 |
⇒ | If not the specified value, replace the relay. |
⇒ | if greater than the specified range, replace the relay. |
⇒ | If the Defogger Indicator does not illuminate, replace the HVAC Control Module |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for HVAC Control Module and BCM replacement, setup and programming. |