Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you review the power door locks circuit description and operation and perform the necessary inspections? | -- | Go to Step 2 | Go to Symptoms |
2 | Verify the fault is present. Does the system operate normally? | -- | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 |
Is continuity present? | -- | Go to Step 6 | Go to Step 4 |
4 |
Is continuity present? | -- | Go to Step 5 | Go to Step 7 |
5 |
Does the test lamp light? | -- | Go to Step 8 | Go to Step 9 |
6 | Replace the power door lock control module. Refer to Door Control Module Replacement . Is the repair complete? | -- | Go to Step 10 | -- |
7 | Repair the open in CKT 150 (BLK) between the side door jamb switch and ground. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Step 10 | -- |
8 | Replace the side door jamb switch. Refer to Sliding Door Jamb Contact Plate Replacement . Is the repair complete? | -- | Go to Step 10 | -- |
9 | Repair the open in CKT 158 (WHT/BLK) between the power door lock control module and the side door jamb switch. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Step 10 | -- |
10 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 3 |