Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you review the power door locks circuit description and operation and perform the necessary inspections? | -- | Go to Step 2 | Go to Symptoms |
2 | Verify the fault is present. Does the system operate normally? | -- | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 |
Does the test lamp light? | -- | Go to Step 4 | Go to Step 8 |
4 | Connect a J 39200 digital multimeter between the power door lock control module connector, cavity A for CKT 150 (BLK), and ground. Is continuity present? | -- | Go to Step 5 | Go to Step 9 |
5 |
Is continuity present? | -- | Go to Step 6 | Go to Step 7 |
6 |
Is continuity present? | -- | Go to Step 10 | Go to Step 11 |
7 |
Does the test lamp light? | -- | Go to Step 13 | Go to Step 12 |
8 | Repair the open in CKT 540 (ORN) between splice S228 and the power door lock control module. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Step 14 | -- |
9 | Repair the open in CKT 150 (BLK) between the power door lock control module and ground. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Step 14 | -- |
10 | Repair the short to ground in CKT 158 (WHT/BLK) between the power door lock control module and the side door jamb switch. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Step 14 | -- |
11 | Replace the side door jamb switch. Refer to Sliding Door Jamb Contact Plate Replacement . Is the repair complete? | -- | Go to Step 14 | -- |
12 | Repair the open in CKT 195 (LT BLU) between splice S241 and the power door lock control module connector, cavity C. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Step 14 | -- |
13 | Replace the power door lock control module. Refer to Door Control Module Replacement . Is the repair complete? | -- | Go to Step 14 | -- |
14 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 3 |