Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you review the power door locks circuit description and operation and perform the necessary inspections? | -- | Go to Step 2 | Go to Symptoms |
2 | Verify the fault is present. Does the system operate normally? | -- | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 | Check the condition of the PWR ACCY Fuse A in the IP fuse block. Is the fuse open? | -- | Go to Step 8 | Go to Step 4 |
4 |
Does the test lamp light? | -- | Go to Step 5 | Go to Step 9 |
5 | Connect a J 39200 digital multimeter between the power door lock relay connector, cavity D for CKT 150 (BLK), and ground. Is continuity present? | -- | Go to Step 6 | Go to Step 10 |
6 |
Is continuity present? | -- | Go to Step 7 | Go to Step 11 |
7 | Connect a J 39200 digital multimeter between the left front power door lock actuator motor connector, cavity B, and the power door lock relay connector, cavity E, for CKT 295 (GRY). Is continuity present? | -- | Go to Step 12 | Go to Step 13 |
8 | Repair the short to ground in CKT 540 (ORN). Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Step 14 | -- |
9 | Repair the open in CKT 540 (ORN) between the IP fuse block and the power door lock relay. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Step 14 | -- |
10 | Repair the open in CKT 150 (BLK) between the power door lock relay and ground G201. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Step 14 | -- |
11 | Repair the open in CKT 294 (TAN) between the power door lock relay and splice S243. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Step 14 | -- |
12 | Replace the power door lock relay. Is the repair complete? | -- | Go to Step 14 | -- |
13 | Repair the open in CKT 295 (GRY) between the power door lock relay and splice S244. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Step 14 | -- |
14 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 3 |