Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you review the power window circuit description and operation and perform the necessary inspections? | -- | Go to Step 2 | Go to Symptoms |
2 | Verify the fault is present. Does the system operate normally? | -- | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 | Check condition of the PWR WDO fuse. Is PWR WDO fuse open? | -- | Go to Step 6 | Go to Step 4 |
4 |
Is continuity present? | -- | Go to Step 5 | Go to Step 7 |
5 |
Does the test lamp light? | -- | Go to Step 8 | Go to Step 9 |
6 | Repair the short to ground in CKT 343 (YEL) between the IP fuse block and the left front or right front power side window switch. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Step 10 | -- |
7 | Repair the open in CKT 150 (BLK) between the left front power side window switch and ground. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Step 10 | -- |
8 | Replace the left front power side window switch. Refer to Front Side Door Window Switch Replacement . Is the repair complete? | -- | Go to Step 10 | -- |
9 | Repair the open in CKT 343 (YEL) between the IP fuse block and splice S229. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Step 10 | -- |
10 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 3 |