Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
DEFINITION: Both vanity mirrors are inoperative, but the stepwell lamps (which are operated by the same fuse) are operating properly. | ||||
1 | Review the sun shade mirror lamp operation and perform the necessary inspections. Did you complete the system review and inspection? | -- | Go to Step 2 | Go to Symptoms |
2 | Ensure that the left sun shade mirror lamp brightness adjustment is not at the minimum. Attempt to operate the sun shade mirror lamp. Does the system operate normally? | -- | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 |
Is the measurement equal to battery voltage? | -- | Go to Step 5 | Go to Step 4 |
4 | Repair the open CKT 40 (ORN) between splice S308 and the sunshade mirror lamp. Did you complete the repair? | B+ | Go to Step 8 | -- |
5 | Test continuity between ground and cavity B of the sunshade mirror lamp connector. Did the test indicate continuity? | -- | Go to Step 7 | Go to Step 6 |
6 | Repair the open CKT 150 (BLK) between splice S204 and the sunshade mirror lamp. Did you complete the repair? | -- | Go to Step 8 | -- |
7 | Replace the sunshade mirror lamp bulb. Did you complete the repair? | -- | Go to Step 8 | -- |
8 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 3 |