• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Relay Switch B+ Circuit | 2 | 2 | -- | -- |
Rear Defogger Relay Control | B0283 02 | B0283 05 | B0283 05 | -- |
Rear Defogger Control Circuit | 2 | 2 | 1 | -- |
Relay Coil Ground | -- | 2 | 2 | -- |
Rear Window Defogger Grid Ground | -- | 2 | 2 | -- |
1. Rear Defogger Always ON 2. Rear Defogger Inoperative |
The HVAC control module monitors the voltage level on the supply voltage circuit of the DEFOG relay. The voltage level should be low while the DEFOG relay is de-energized. The voltage will be near system voltage when the HVAC control module energizes the DEFOG relay.
Battery voltage must be between 9-16 volts.
This DTC will set when the HVAC control module detects a short to ground in the rear defog relay control circuit for 1 second or greater.
This DTC will set when the HVAC control module detects a short to voltage or an open/high resistance in the rear defog relay control circuit for 1 second or greater.
• | The HVAC Control Module stores the DTC to memory. |
• | The rear window defogger will not operate. |
• | This DTC will change from current to history when the fault is no longer present. |
• | A history DTC will clear after 100 consecutive ignition cycles if the condition for the malfunction is no longer present. |
• | The technician issues a scan tool CLEAR DTCs command. |
Window Systems Connector End Views
Rear Window Defogger Description and Operation
Command the rear window defogger ON and OFF with the scan tool. The rear window defogger should turn ON and OFF when changing between the commanded states.
⇒ | If greater than the specified range, test the relay coil ground circuit for an open/high resistance. |
⇒ | If the test lamp is always ON, test the rear defogger relay control circuit for a short to voltage. If the circuit tests normal, replace the HVAC control module. |
⇒ | If the test lamp is always OFF, test the rear defogger relay control circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the HVAC control module. |
⇒ | If the resistance is not within the specified range, replace the relay. |
• | 30 and 86 |
• | 30 and 87 |
• | 30 and 85 |
• | 85 and 87 |
⇒ | If not the specified value, replace the relay. |
⇒ | If greater than the specified range, replace the relay. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for HVAC control module and BCM replacement, setup and programming |