• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
B+ | B1325 03, B1325 4A | B1325 03, B1325 4A | -- | -- |
Ground | -- | B1325 03, B1325 4A | -- | -- |
The control modules on this vehicle monitor the voltage on the battery positive (B+) voltage circuits. The following modules on this vehicle will set DTC B1325 if high or low battery voltage is detected:
• | Instrument panel cluster (IPC) |
• | Passenger presence system (PPS) |
• | Radio |
• | The battery voltage supplied to the control modules is in the range of 7-26 volts. |
• | The ignition is ON |
The control module detects that the system voltage is less than 9 volts for 5 seconds.
The control module detects that the system voltage is greater than 18 volts for 5 seconds.
The IPC failed the power on checksum test, either due to low voltage or corrupted memory.
• | The control module immediately disables all outputs when an out of range voltage condition has been detected, with the exception of GMLAN, which is disabled after a 3 minute delay. |
• | The setting of other DTCs is inhibited. |
The DTC clears when the malfunction is no longer present.
• | A high or low voltage value in multiple modules indicates a concern in the charging system. |
• | Overcharging with a battery charger or jump starting can cause this DTC to set. |
Charging System Description and Operation
⇒ | If not within the specified range, refer to Charging System Test . |
• | Terminal 6 (IPC) |
• | Terminal D (PPS) |
• | Terminal 8 X1 (Radio) |
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. |
• | Terminal 14 (IPC) |
• | Terminal A (PPS) |
• | Terminal 1 X1 (Radio) |
⇒ | If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
Control Module References for the appropriate module replacement, setup, and programming.