Removal Procedure
- Remove the I/P assembly. Refer to
Instrument Panel Assembly Replacement
in Instrument
Panel, Gages and Console.
- Remove the retaining screws from the right floor air outlet duct.
- Disconnect the air outlet duct from the HVAC module.
- Remove the air outlet duct.
Installation Procedure
- Install the air outlet duct.
- Connect the air outlet duct to the HVAC module.
Notice: Refer to Fastener Notice in the Preface section.
- Install the air outlet duct retaining screws.
Tighten
Tighten the screws to 1.6 N·m (14 lb in).
- Install the I/P assembly. Refer to
Instrument Panel Assembly Replacement
in Instrument Panel, Gages and Console.