The powertrain control module (PCM) uses the generator turn on signal circuit to control the generator. A high side driver within the PCM allows the PCM to turn the generator ON and OFF. When Generator operation is desired, the PCM sends a 12 volt signal to the voltage regulator via the generator turn on signal circuit. This causes the voltage regulator to begin controlling the generator field circuit. Once the Generator is enabled by the PCM, the voltage regulator controls generator output independently of the PCM by monitoring the battery positive voltage sense circuit. Under certain operating conditions, the PCM can turn Off the generator by turning Off the 12 volt signal on the generator turn on signal circuit. The PCM has fault detection circuitry which monitors the state of the generator turn on signal circuit. If the fault detection circuit senses a voltage other than what is expected, this DTC will set. The voltage regulator also contains fault detection circuitry. If the regulator detects a problem, the regulator will ground the generator turn on signal circuit, pulling the voltage low. This also causes the PCM to set the DTC.
• | The Key is in the ON position for 5 seconds. |
• | The engine is OFF. |
• | The engine is running. |
• | The engine speed is less than 3000 RPM. |
During the RUN test, the PCM detects a low signal voltage on the generator turn on signal circuit for at least 5 seconds.
• | The PCM sends a class 2 message to the IPC to illuminate the charge indicator and/or turn on a message. |
• | The PCM will not illuminate the malfunction indicator lamp (MIL). |
• | The PCM will store the conditions present when the DTC set as Fail Records data only. |
• | The history DTC will clear after 40 consecutive warm-up cycles have occurred without a malfunction. |
• | The DTC can be cleared by using the scan tool Clear DTC Information function. |
Step | Action | Value | Yes | No |
---|---|---|---|---|
Schematic Reference: Starting and Charging Schematics | ||||
1 | Did you perform the Engine Electrical Diagnostic System Check? | -- | Go to Step 2 | |
2 |
Does the scan tool indicate that DTC P1637 has passed? | -- | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 |
Does the voltage measure near the specified value? | 12.0 V | Go to Step 5 | Go to Step 4 |
4 | Test the generator turn on signal circuit for a short or open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 11 | Go to Step 8 |
5 | Test the generator battery positive voltage sense circuit for a high resistance or open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 11 | Go to Step 6 |
6 | Test the generator battery positive voltage output circuit for a high resistance or open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 11 | Go to Step 7 |
7 | Inspect for poor connections at the harness connector of the generator. Refer to Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 11 | Go to Step 9 |
8 | Inspect for poor connections at the harness connector of the PCM. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 11 | Go to Step 10 |
9 | Replace the Generator. Refer to Generator Replacement . Did you complete the replacement? | -- | Go to Step 11 | -- |
10 |
Important: The replacement PCM must be programmed. Refer to Powertrain Control Module Programming in Engine Controls 5.7L. Replace the PCM. Refer to Powertrain Control Module Replacement in Engine Controls 5.7L. Did you complete the replacement? | -- | Go to Step 11 | -- |
11 |
Does the DTC reset? | -- | Go to Step 3 | System OK |