Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.
Tighten
Tighten the upper retractor bolt to 41 N·m (31 lb ft).
Tighten
Tighten the lower retractor bolt to 47 N·m (35 lb ft).
Tighten
Tighten the upper guide bolt to 41 N·m (31 lb ft).
Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.
Tighten
Tighten the upper retractor bolt to 41 N·m (30 lb ft).
Tighten
Tighten the lower retractor bolt to 41 N·m (30 lb ft).
Tighten
Tighten the upper lock pillar trim panel screw to 1.8 N·m
(16 lb in).
Tighten
Tighten upper guide nut to 40 N·m (29 lb ft).