Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
Schematic Reference: Instrument Cluster Schematics | ||||
1 | Did you perform the IPC Diagnostic System Check? | -- | Go to Step 2 | |
2 |
Does the volt gage move up and down when commanded? | -- | Go to Step 3 | |
3 | With a scan tool, observe the Ignition 1 parameter in the IPC data 1 list. Does the scan tool indicate that the Ignition 1 parameter is within the specified range? | 8.0-16.0 V | Go to Step 4 | Go to Step 5 |
4 | With a scan tool, observe the Ignition 1 parameter in the IPC data 1 list and the voltage gage display on the IPC. Does the scan tool display correspond with the voltage gage display within the specified value? | 0.5 V | System OK | |
5 | Test the ignition positive voltage circuit of the IPC for a short to ground or an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 7 | Go to Step 6 |
6 | Replace the IPC. Refer to Instrument Cluster Replacement . Did you complete the replacement? | -- | Go to Step 7 | -- |
7 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 2 |